Description:
HMS Industrial Networks AB was founded in 1988. From its headquarters in Sweden, HMS has expanded its operations with offices and support centers in the United States, Japan, Germany and a distributor network covering five continents. HMS develops, produces and markets intelligent communication technology for automation devices. Its technology, services and products bring value and flexibility to manufacturers and users of automation products. HMS's AnyBus product line includes embedded solutions, serial and Ethernet bridges, gateways, and switches, as well as a full set of development tools.See list of news items about this company...
| Product Name | Type | Connectivity | Product Description |
|---|---|---|---|
| Anybus Communicator - Ethernet Modbus-TCP to Serial RS232/422/485 Gateway, AB7007 | Network Gateway | Modbus TCP/IP | The Anybus Communicator Gateway is an external DIN-rail mounted gateway which provides Ethernet Modbus-TCP network connectivity via a serial RS232/RS422/RS485 interface. The Communicator contains an embedded Modbus-TCP and EtherNet/IP 10/100 Mb interface with IT functionality such as WEB-server, Flash file system, FTP-server, e-mail client, Telnet etc. The Communicator performs an intelligent conversion between the serial protocol and the chosen industrial network. The translation between the serial protocol and the network is configured by using the software "ABC Config Tool". |
| Anybus-S Embedded Modbus-TCP/IP module, AB4172 | I/O Interface | Modbus TCP/IP | The Anybus-S Ethernet module is a 10- or 100-Mbps interface with a full TCP/IP protocol stack embedded. The module also supports IT functionality such as a WebServer for creating Dynamic Webpages, including reading and writing of DPRAM data, e-mail sending, and FTP for downloading of user webpages. Through the mailbox socket interface, the module provides the possibility of implementing other TCP/UDP protocols using the modules TCP/IP stack. |
| Anybus-S Embedded Modbus-RTU Module, AB4172 | I/O Interface | Modbus RTU | The Anybus-S Modbus RTU is available with a 2k parallel Dual Port Ram interface. Modbus station address and baud rate can be selected via switches on the front side of the module or by software via the application interface. A bus termination switch is located on the front side of the module. A DC/DC converter and optocouplers are provided onboard. |
| AnyBus Communicator Serial to Modbus Plus Gateway, AB7002 | Network Gateway | Modbus | The AnyBus Communicator Gateway for Modbus Plus is an external DIN-rail mounted gateway which provides Modbus Plus network connectivity via a serial RS232/RS422/RS485 interface. The communicator contains a conformance tested AnyBus-S Modbus Plus interface and therfore has the same standard Modbus Plus services as the ABS slave module. It has serial protocol support for Modbus RTU Master Mode and Generic Data Mode which is fully configurable through the New ABC Config Tool V1.5 and the PC port on the AnyBus Communicator. Other protocols can be implemented by HMS on request. |
| Embedded AnyBus-S Modbus Plus Slave Interface, AB4080 | I/O Interface | Modbus | Embedded high performance interchangeable Modbus Plus slave interface card that handles 2kbytes of input data and 2kbytes of output data. The AnyBus-S Modbus Plus module supports global database transaction. The dynamic mailbox interface also provides the possibility to set the node ID, set the source ID (for global data) and also get/clear the network statistics. The AnyBus-S range consists of over 15 interchangeable Fieldbus interfaces for all major Fieldbus networks. |
| Gateway LonWorks-Modbus RTU, AB7009 | Network Gateway | Modbus | This is a gateway between LonWorks and Modbus RTU. The gateway is a SLAVE on the Modbus RTU side. This means that you connect this to a Modbus network which has a MASTER. The configuration of the module is simple and you can do it yourself with a configuration tool from us. |
| Anybus Communicator - Modbus-RTU to Serial RS232/422/485 Gateway, AB7014 (with RS-232 on RTU slave side); AB7010 (with RS-485 on RTU slave side) | Network Gateway | Modbus RTU | The Anybus Communicator Gateway is an external DIN-rail mounted gateway which provides Modbus-RTU slave connectivity on one side and a configurable serial RS232/RS422/RS485 on the lower side. The Communicator contains an embedded high-performance Modbus-RTU interface that performs an intelligent conversion between the serial protocol and the chosen industrial network. The translation between the serial protocol and the network is configured by using the software "ABC Config Tool". |
| Anybus CompactCom - Ethernet Modbus-TCP Plug-in module, AB6204 | I/O Interface | Modbus TCP/IP | Anybus CompactCom (Anybus-CC) modules are designed for integration into industrial devices that need to communicate with other automation equipment via Ethernet Modbus TCP or any other major network. Anybus-CC is the latest range of cost-optimized plug-in modules supporting all major Fieldbus and Ethernet networks. The Anybus-CC provides optimal flexibility for OEM device manufacturers. Powered by the new Anybus NP30 ASIC, Anybus-CC provides both the performance and functionality required to meet the communication demands of HMIs, Robot controllers, Drives, PLCs Valve blocks, Instruments, Weigh scales and other industrial products. Anybus-CC uses the CompactFlash? connector. The modules are completely covered by a robust plastic housing that enables easy handling at any time in the logistic chain between manufacturer and end customer. |
| Anybus CompactCom - Modbus-RTU Plug-in module, AB6203 | I/O Interface | Modbus RTU | Anybus CompactCom (Anybus-CC) modules are designed for integration into industrial devices that need to communicate with other automation equipment via Modbus-RTU or any other major network. Anybus-CC is the latest range of cost-optimized plug-in modules supporting all major Fieldbus and Ethernet networks. The Anybus-CC provides optimal flexibility for OEM device manufacturers. Anybus-CC provides the performance and functionality required to meet the communication demands of HMIs, Robot controllers, Drives, PLCs Valve blocks, Instruments, Weigh scales and many more industrial products. Anybus-CC uses the CompactFlash? connector. The modules are completely covered by a robust plastic housing that enables easy handling at any time in the logistic chain between manufacturer and end customer. |
| Anybus-IC Embedded Ethernet Modbus-TCP Hybrid Chip, AB6002 | I/O Interface | Modbus TCP/IP | The Anybus-IC is a complete single-chip controller for industrial networks. It is optimized for low-/medium-range field devices, such as measuring devices, I/O blocks, valve manifolds, and temperature controllers where small size and multiple network connectivity is important. Anybus-IC is built on hybrid technology and contains all the analog and all digital components necessary to implement a network interface. A powerful 16/32 bit microcontroller with Flash and RAM memory, a network protocol chip and all necessary analog components including optocouplers, a DC/DC converter and bus drivers are integrated in a single housing of only 9 cm? in size. |
| Anybus X - Modbus-TCP to CANopen Gateway, AB7640 | Network Gateway | Modbus TCP/IP | Anybus X-gateways are designed for use in Industrial Automation plants where increasingly many different Fieldbus and Ethernet networks are used. The X-gateways help System Integrators to easily interconnect Modbus TCP/IP, Modbus Plus, or Modbus RTU to virtually any other network, enabling consistent information flow throughout the entire plant. The Ethernet interface consists of an embedded Modbus TCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, and Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32-bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave's data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organization and has proven conformance and interoperability with leading PLCs, SoftPLCs, HMIs and other devices. |
| Anybus X - Modbus TCP/IP to CC-Link Gateway, AB7643 | Network Gateway | Modbus TCP/IP | The Anybus X-gateways are designed for use in Industrial Automation plants where increasingly many different Fieldbus and Ethernet networks are used. The X-gateways help System Integrators to easily interconnect Modbus TCP/IP, Modbus Plus, or Modbus-RTU to virtually any other network, enabling consistent information flow throughout the entire plant. The Ethernet interface consists of an embedded Modbus-TCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32-bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLCs, HMIs and other devices. |
| Anybus X - Modbus TCP/IP to ControlNet Gateway, AB7636 | Network Gateway | Modbus TCP/IP | The Anybus X-gateways are designed for use in Industrial Automation plants where increasingly many different Fieldbus and Ethernet networks are used. The X-gateways help System Integrators to easily interconnect Modbus TCP/IP, Modbus Plus, or Modbus-RTU to virtually any other network, enabling consistent information flow throughout the entire plant. The Ethernet interface consists of an embedded Modbus-TCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32-bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLCs, HMIs. |
| Anybus X-gateway - Modbus TCP/IP to DeviceNet Adapter/Slave Gateway, AB7635 | Network Gateway | Modbus TCP/IP | Anybus X-gateways are designed for use in Industrial Automation plants where increasingly many different Fieldbus and Ethernet networks are used. The X-gateways help System Integrators to easily interconnect Modbus TCP/IP, Modbus Plus, or Modbus-RTU to virtually any other network, enabling consistent information flow throughout the entire plant. The Ethernet interface consists of an embedded Modbus-TCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32-bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The high-performance DeviceNet Slave interface provides instant connectivity to the DeviceNet network. The module conforms to DeviceNet 2.0. The DeviceNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLCs, HMIs. Baud rate and MAC ID can be set via DIP switches. |
| Anybus X-gateway - Modbus TCP/IP to DeviceNet Scanner/Master Bridge/Gateway, AB7630 | Network Gateway | Modbus TCP/IP | Anybus X-gateways are designed for use in Industrial Automation plants where increasingly many different Fieldbus and Ethernet networks are used. The X-gateways help System Integrators to easily interconnect Modbus TCP/IP, Modbus Plus, or Modbus-RTU to virtually any other network, enabling consistent information flow throughout the entire plant. The Ethernet interface consists of an embedded Modbus-TCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32-bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the AnyBus-M module via the HMS configuration software NetTool-DN (purchased as a separate accessory) or via Rockwell?s RSNetWorx. |
| Anybus X Gateway - Modbus-TCP to J1939, AB7665 | Network Gateway | Modbus TCP/IP | This Anybus X-gateway provides connectivity between ModbusTCP and a J1939 Heavy Duty vehicle (CAN) network. The X-gateway appears as a ModbusTCP slave/server allowing a ModbusTCP master/client to read or write data from the J1939 network. HMS provides the X-gateway with a Windows-based configuration tool (BWConfig). This PC-based software allows users to map J1939 parameter (PGN) data into a range of memory addressable through the X-gateway ModbusTCP interface. Configuration of the X-gateway is simple using BWConfig and consists of setting up an I/O table containing selected J1939 PGNs and the rate that each will be read to or written from the J1939 network. BWConfig then automatically maps the I/O table to a range of addresses accessible from the X-gateway ModbusTCP interface. The configuration is downloaded from the PC to the X-gateway on an RS232 connection and is saved in FLASH memory. |
| Anybus X-gateway - Modbus RTU Slave to CC Link Slave, AB7621 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLCs, HMIs. |
| Anybus X Gateway - Modbus RTU Slave to Modbus Plus Slave, AB7620 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. The Modbus Plus interface is based on licensed chip-set and software from Schneider Electric. Supporting both the Global Database and Register mapping to 3x and 4x registers this module implements a versatile Modbus Plus interface. The Modbus Plus interface module is certified by the Modconnect and has proven conformance and interoperability with leading PLCs, HMIs. |
| Anybus X Gateway - Modbus RTU Slave to ControlNet Adapter/Slave, AB7869 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Profibus Slave Gateway, AB7850 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Profibus DP/DPV1 slave interface is implemented according to the standard IEC61158 as a modular slave, supporting all standard functionality such as Watchdog, Sync and Freeze and diagnostics. Standard DP as well as DPV1 acyclic data services (Class1/Class2) are supported. The Profibus interface module is certified by the Profibus user organization and has proven conformance and interoperability with leading PLCs, HMIs. Profibus address is set via rotary switches 0-99. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Profinet IO Device, AB7659 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Profinet IO interface is a complete solution for a Profinet IO slave Device. The module is based on the Siemens Profinet IO software technology. The Profinet IO baudrate is 100Mbps (full duplex). The IP-address and additional IP-settings is configured with the Anybus IPconfig utility for Windows. Additional ways to set the IP-address are either via DHCP or the Profinet configuration tool. Four diagnostic LEDs continuously indicate the actual Profinet IO status and possible error messages. The Profinet IO interface uses a normal RJ45 connector for the bus connection. IT-functions like Web-server, e-mail client, FTP-server are supported. IT functions can be used simultaneously with the Profinet IO communication. Modbus/TCP is also supported with "Read Data" functions. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Ethernet Modbus TCP Slave Gateway, AB7641 | Network Gateway | Modbus, Modbus TCP/IP | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is simple and carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. This gateway is a true Layer 7 gateway that converts application data to/from Ethernet Modbus/TCP <=> Modbus RTU, providing independent handling of each communication interface. For a transparent gateway between Ethernet Modbus/TCP <=> Modbus RTU, please look at the HMS part number AB7702. The Ethernet interface consists of an embedded ModbusTCP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32 bit RISC micro processor (+60 mips) ensuring fast and secure Ethernet performance. The EtherNet/ModbusTCP interface module has proven interoperability with leading PLCs, HMIs, other devices. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Modbus RTU Slave Gateway, AB7899 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The gateway consists of two independent ModBus-RTU Slave interfaces, logically and galvanically separated. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to CANopen Slave Gateway, AB7895 | Network Gateway | Modbus | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The CANopen interface is an adapter class product allowing fast data exchange. The CANopen slave's data map consists of Process Data Objects (fast data) and Service Data Objects (slow data). The data on the CANopen bus is updated when a change is made or on request from another node. The CANopen interface module is certified by the Can In Automation organisation (CANopen conformance: CIA DS-301 V3.0) and has proven conformance and interoperability with leading PLCs, SoftPLCs, HMIs. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Interbus Slave FO Gateway, AB7890 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Interbus 2Mbps interface with a Fiber Optic bus-interface is an important complement to the standard module for copper-based cabling. The Fiber Optic module is based on the OPC chipset from Phoenix, which gives support for optical diagnostics. This means the unit has a high EMC immunity and also a very low EMC emission. The Interbus interface 2Mbps module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called 'Process Data', and one through a somewhat slower protocol called PCP, mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to Interbus Slave Cu Gateway, AB7884 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Interbus 2Mbps interface module is a slave node that can be read from/written to by an Interbus master. Interbus has two ways of exchanging data; one through fast cyclical I/O data called 'Process Data', and one through a somewhat slower protocol called PCP, mainly used for configuration purposes. It supports Interbus PCP V2.0. The module supports up to 10 words of data on the bus, out of which up to four words can be used for PCP. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to FIP Slave Gateway, AB7877 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The FIPIO interface is based an embedded AnyBus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer connection on the module provides a isolated fieldbus interface. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baud rate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to DeviceNet Adapter/Slave Gateway, AB7860 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The high performance DeviceNet Slave interface provides instant connectivity to the DeviceNet network. The module conforms to DeviceNet 2.0. The DeviceNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLCs, HMIs and other devices. Baud rate and MAC ID can be set via DIP switches. The Modbus RTU Slave interface is implemented according to Modbus Protocol implementation guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X - Modbus RTU Slave to J1939, AB7612 | Network Gateway | Modbus RTU | The Anybus-X J1939 Gateway provides connectivity between a Modbus RTU (serial) network and a J1939 Heavy Duty vehicle (CAN) network. The ABX appears as a Modbus Slave device allowing a Modbus Master to read or write data from the J1939 network. HMS provides the ABX with a Windows based configuration tool (BWConfig). This PC based software allows the user to map J1939 parameter (PGN) data into a range of memory addressable through the ABX Modbus RTU interface. The ABX is configured using BWConfig and consists of setting up an I/O table containing selected J1939 PGNs and the rate that each will be read or written from the J1939 network. BWConfig will automatically map the I/O table to a range of addresses accessible from the ABX Modbus RTU interface. The configuration is downloaded from the PC to the ABX via an RS232 connection and is saved in FLASH memory. |
| Anybus X - Modbus RTU Slave to Ethernet/IP/Adapter/Slave, AB7839 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Ethernet interface consists of an embedded Ethernet/IP 10/100 Mbps interface with IT functionality such as Web-server, SSI-scripts, Flash file system, FTP-server, e-mail client, Telnet. It is possible to build web pages displaying and controlling a factory floor process with data from the other connected network. It is built on a dedicated 32 bit RISC micro processor (+60 mips). The EtherNet/IP interface module is certified by the ODVA and has proven conformance and interoperability with leading PLCs, HMIs. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X Gateway - Modbus RTU Slave to AS-Interface Master, AB7828 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The AnyBus-M AS-Interface Master module supports up to 62 slaves with a maximum of 248 digital input, 186 output signals. All standard services are available including detailed diagnostics. The network interface is optically isolated and equipped with a two-pin pluggable screw connector. The Master supports intelligent auto-configuration or manual configuration via terminal program such as Hyper Terminal for Windows. The AS-interface module is certified by the AS Interface user organization and has proven conformance and interoperability with leading manufacturers of I/O, sensors, valves etc. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X Gateway - Modbus RTU Slave to DeviceNet Scanner/Master, AB7817 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the AnyBus-M module via the HMS configuration software NetTool-DN (purchased as a separate accessory) or via Rockwell?s RSNetWorx. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus X Gateway - Modbus RTU Slave to Profibus Master, AB7808 | Network Gateway | Modbus RTU | The Anybus-X gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows. The Profibus interface module is certified by the Profibus user organization and has proven conformance and interoperability with leading manufacturers of I/O, drives, instruments etc. Configuration is downloaded to the module via the RS232 configuration port. The Modbus RTU Slave interface is implemented according to Modbus Protocol ref guide (PI-MBUS-300). All data is mapped to 3x and 4x Modbus areas meaning the Input Status and Output Register Word areas. The Modbus RTU standard baudrate is 19200 Bit/s but can be modified on the gateway between 1200 Bit/s to 57 600 Bit/s. |
| Anybus RemoteCom | Monitoring Hardware | Modbus, Modbus TCP | Remote management device for use in applications such as factory and process automation, generator power stations, and heating and ventilation equipment in building control. The integrated alarm and status handler automatically notifies remote supervisors via SMS or e-mail if pre-defined limits are exceeded. |
| Anybus-S EtherNet/IP 2-Port Communication Module, AB4582 | Network Gateway | Modbus, Modbus TCP | The Anybus-S EtherNet/IP 2-Port communication module provides instant integration in any Ethernet-based LAN via SMTP, FTP, Telnet, HTTP as well as EtherNet/IP and Modbus TCP. Additional protocols can be implemented on top of TCP/IP or UDP using the transparent socket interface. |
News items about this company:
Bridging Profibus and Modbus-TCP networks with an Anybus X-gateway
The X-gateway is a configurable stand-alone gateway that allows plant-floor devices on a Profibus network to communicate with the devices on a Modbus-TCP network and vice versa.
Click here for more information...
Anybus New Embedded EtherNet/IP Two-port Module
The new EtherNet/IP module with integrated 2-port switch is the latest addition to the Anybus-S family. The module provides instant integration in any Ethernet-based LAN via SMTP, FTP, Telnet, HTTP as well as EtherNet/IP and/or Modbus TCP.
Click here for more information...
HMS Announces Profibus to Modbus Converter
The Anybus Communicator is an intelligent protocol converter that connects automation devices via their serial Modbus interface to Profibus networks. The Communicator provides instant Profibus connectivity. The automation device remains unchanged and there is no need for hardware or software modifications or extensive engineering work.
Click here for more information...
Emotron's FDU/VFX Variable Speed Drives Support Modbus TCP with Plug-in Anybus Module from HMS
Emotron FDU/VFX variable speed drives now support communication via industrial Ethernet using Modbus TCP.
Click here for more information...
HMS Industrial Networks introduces Anybus RemoteCom
With Anybus RemoteCom, HMS Industrial Networks introduces a new product series for remote management and control of automation devices. Anybus RemoteCom is equipped with a powerful internal web server for remote access of device data including data logging and trend graph presentation. Anybus RemoteCom connects locally to any automation device equipped with a standard serial Modbus-RTU interface.
Click here for more information...
HMS' New Anybus Communicator Serial Gateway Supports EtherCAT Protocol
The new EtherCAT gateway is the latest member of the Anybus Communicator family. The product connects automation devices via their serial RS-232/-422/-485 interface to EtherCAT. The Anybus Communicator family now supports 14 fieldbus and industrial Ethernet networks providing external network connectivity to all kind of automation devices.
Click here for more information...
HMS works with MatrikonOPC
Expanded connectivity for HMS Anybus PCI Cards with OPC Technology
HMS Industrial Networks is proud to announce its choice of MatrikonOPC, a division of Matrikon Inc., as its vendor for full OPC connectivity to Anybus-PCI cards and Anybus X-gateways.
Click here for more information...
Copyright © 2005-2010 Modbus Organization, Inc. PO Box 628 Hopkinton, MA 01748. All rights reserved.
By using Modbus.org, you accept the terms of our visitor agreement and privacy policy.